TCA-TBA REMOVAL
Equipment

Winetech TCA - TBA Removal system: chromatographic method: adsorbent resin column + pump

Pat # 6,610,342

Applications Removal of TCA and TBA from wine.
Compliance

All components, materials and chemicals are FDA approved.
BATF status: approved

Process

Equipment available to treat from 1 barrel and up.
Removal rate: 100%
All equipment is sanitized after each use.

Service Requirements

Power: 110 V or compressed air

Nitrogen

Receptacle: Hubbell style three poles + ground 30 A 480V / 60 A 480V / 60 A 240V NO HARD WIRING will be done by our Filter Technicians. We can sell the receptacle to be installed by your contractor. We will not perform the service without the necessary receptacle in place.

Water: Within 70 feet with 3/4" garden hose fitting.

Tanks: Wine tank within 70’ with Tri Clover fitting (above ground level). Sanitized tank.

Hoses: 1 1/2" or 2" , clean, enough to reach the tanks.

 

Wine Requirements

Wine:Racked, blended in tank.
Lot size:N/A
Wine temperature: N/A

Caution: maintain free SO2 level between 20 – 30 mg/l before and after treatment


Home | Mobile Filtration Services | Crossflow Equipment | Technical Literature | Contact Us


Copyright 2007 - Winetech.us - Web Design BRPacific.com